- Electrical Wires[10]
- Power Cables[10]
- Control Cables[7]
- Communication Cables[5]
- Welding Rods[1]
- Solar Energy Systems[1]
- Other Wires[5]
- Telephone Cords[3]
- Aluminum Wire[3]
- Metal Building Materials[2]
- Instrumentation Cables[1]
- Contact Person : Mr. Yuan Jed
- Company Name : Zhengzhou Hesheng Cable Co., Ltd.
- Tel : 0086-0371-68611580
- Fax : 0086-0371-68628536
- Address : Henan,Zhengzhou,Lijianggou Village Zhongyuan Distrcit
- Country/Region : China
- Zip : 450006
Power Transmission Cable XLPE Insulated Power Cable
Power Transmission Cable XLPE Insulated Power Cable
1). Standard: IEC60502; GB12706.1-2002
2). Application: For laying indoors, underground, in tunnel or cable trench.
3). Specification:
CU/Aluminium conductor for single core or multi-core;
XLPE insulated;
SWA(steel wire armoured);
PVC sheathed power cable.
4). Voltage: 0.6/1KV, 3.6/6, 6/10, 8.7/15, 12/20, 18/30, 21/35KV
5). Power Cable feature
1. Max Long-time operating temperature of XLPE insulated cable is 90°C.
2. Installing temperature of cable should not be less than 0°C.
3. Max short-circuit temperature is not exceed 250°C, not more than 5 sec.
Power Transmission Power Cable Technical Parameter
type | No. of cores | 0.6/1 KV | 6/6KV 6/10KV | 8.7/15KV 12/20KV 18/30KV | 19/33KV 26/35KV |
Cross section/mm2 | |||||
Copper/XLPE/PVC | 1 | 1.5-800 | 25-800 | 35-1200 | 50-1200 |
Aluminum/XLPE/PVC | 2.5-1000 | 25-1000 | 35-1200 | 50-1200 | |
Copper/XLPE/SWA(STA)/PVC | 10-1000 | 25-1000 | 35-1200 | 50-1200 | |
Copper/XLPE/PVC | 3 | 1.5-400 | 25-400 | 35-400 | 50-400 |
Aluminum/XLPE/PVC | 2.5-400 | 25-400 | 35-400 | 50-400 | |
Copper/XLPE/SWA/PVC | 4-400 | 25-400 | 35-400 | 50-400 |
Type | Designation | Applications |
YJV YJLV | Copper/XLPE/PVC Aluminum/XLPE/PVC | unable to bear external mechanical forces. Single core cable is not permissible to lay in magnetic duct. |
YJY YJLY | Copper/PE/PVC Aluminum/PE/PVC | |
YJV22 YJLV22 | Copper/XLPE/STA/PVC Aluminum/XLPE/STA/PVC | able to bear external mechanical forces, but unable to bear large pulling force. |
YJV23 YJLV23 | Copper/PE/STA/PVC Aluminum/PE/STA/PVC | |
YJV32 YJLV32 | Copper/XLPE/SWA/PVC Aluminum/XLPE/SWA/PVC | able to bear external mechanical forces, but unable to bear large pulling force. |
YJV33 YJLV33 | Copper/PE/SWA/PVC Aluminum/PE/SWA/PVC | |
Note: The armoured single core cables is only used for D.C. system. As for A.C. system, non-magnetic armour material should be applied. |
Power Transmission Cable XLPE Insulated Power Cable